Jiangsu Zhitai New Energy Technology Co., Ltd

Provide High Quality Energy Solution for Global Customer

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Sodium Ion Battery Cell /

Sodiumion Battery Cell 3V 200Ah 0.2C Discharge Prismatic Type

Contact Now
Jiangsu Zhitai New Energy Technology Co., Ltd
Visit Website
Province/State:jiangsu
Country/Region:china
Contact Person:MsAVA
Contact Now

Sodiumion Battery Cell 3V 200Ah 0.2C Discharge Prismatic Type

Ask Latest Price
Video Channel
Brand Name :ZT-TEK
Model Number :72174204-200Ah
Certification :CE
Place of Origin :China
MOQ :1
Payment Terms :L/C, T/T
Supply Ability :4GWh/Y
Delivery Time :1month
Packaging Details :Carton box
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Sodium-ion battery Cell 3V 200Ah prismatic type

Suitable for extremely cold area

3.1 Nominal Capacity: 200Ah 0.2C discharge
3.2 Nominal Voltage: 3V 0.2C discharge
3.3 AC Impedance : ≤0.28mΩ 30%SOC
3.4 Standard Charge Current:100A 0.5C
3.5 Max. Constant Charge Current:160A 0.8C
3.6 Charge Voltage Limit: 3.9V
3.7 Max. Constant Discharge Current:200A 1.0C
3.8 Max. Plus Discharge Current:300A 1.5C-10s
3.9 Cut-off Voltage:2.0V
3.10 Charge Operation Temperature: -20~55℃

3.11 Discharge Operation Temperature:-30~55℃
3.12 Cell Weight:5KG±0.25KG

3.13 Self discharge : ≤3%/month 25±2℃,30%SOC,

Count after 3 month of 30%SOC fresh cell

Cell Performance Criteria

Visual inspection

There shall be no such appearance defect as stains, crack, leakage, etc.

Standard environmental test condition

Unless otherwise specified, all tests stated in this Product Specification are conducted at below conditions:

Temperature: 25 ± 2 °C

Relative Humidity: 65 ± 20%

Standard charge

Under the standard test condition,charging the cell with constant current at 0.5C to 4.0V and then with constant voltage at 4.0V till charge current declines to 0.05C.

Electrical characteristics

Items Test Method and Condition Criteria
Minimum capacity at
0.2C
Charge the cell under standard test condition and
discharge the cell to 2.0V with 0.2C current, then get
the capacity
≥200Ah
Initial impedance Internal resistance measured at 1KHz at 30%SOC. ≤0.28mΩ
Cell Voltage As of shipment 2.950~3.000V
Cycle Life (25±2℃) Test condition:
Charge:0.5 C to 4.0V,CV to 0.05C
Discharge:1.0C to 2.0V
When capacity declines to 80% of the first cycle
capacity,stop the test.
≥4000
H/L temperature
discharge
Full charge the cell by standard charge condition,
displace in -20±2℃ chamber for 8h, then discharge the
cell at 0.5C to 1.5V

Full charge the cell by standard charge condition, displace in 55±2℃ chamber for 5h, then discharge the
cell at 0.5C to 2.0V.
Capacity remain
≥85% Initial capacity

Capacity remain
≥95% Initial capacity
RT storage performance The capacity on 0.5C discharge (residual capacity) shall
be measured after standard charge and then storage at
25±2℃ for 30 days

After above test,cycle the cell with 0.5C/0.5C for 3
times, select the max capacity as the recovery capacity.
Residual capacity ≥
95%


Recovery capacity
≥98%
HT storage
performance
The capacity on 0.5C discharge (residual capacity) shall
be measured after standard charge and then storage at
55±2℃ for 7 days.

After above test,cycle the cell with 0.5C/0.5C for 3
times, select the max capacity as the recovery capacity

Residual capacity ≥
90%

Recovery capacity
≥95%

Safety and Reliability

Items Test Method and Condition Criteria
Overdischarge Full charge the cell by standard charging method,
discharge the cell 90min using 1.0C, then observe for 1h
under test environment temperature.
No fire, No explosion.
Overcharge Full charge the cell by standard charging method, charge
the cell to 4.4V using 0.5C, then observe for 1h under
test environment temperature
No fire, No explosion.
External short Full charge the cell by standard charging method,
connect the positive and negative tabs with a load less
than 5mΩ for 10min, then observe for 1h under test
environment temperature
No fire, No explosion.
Heating Full charge the cell by standard charging method,
displace the cell into temperature chamber, use
following temperature rising method heating cell: rising
to 130±2 ℃ at a rate of 5℃/min from room temperature,
stay at 130℃ for 30min, stop heating, then observe for
1h under test environment temperature.
No fire, No explosion.
Temperature cycle Full charge the cell by standard charging method,
displace the cell into temperature chamber, use
following method adjust chamber temperature, cycle for
5 times, then observe for 1h under test environment
temperature.
No fire, No explosion.
Crush Full charge the cell by standard charging method, use a
half cylinder with Φ75mm to squeezing the
cell(perpendicular direction) and the move speed is less
than 2mm/s. When the cell voltage declines to 0V or the deformation reaches 15% or the extrusion force reaches
2.67KN, stop then hold for 10min, observe for 1h under
test environment temperature
No fire, No explosion.