Add to Cart
20Ft containerized DC Battery Bank ZT-EES-2411-51314 for power station
Pre-fabricated battery bank with Lithium iron phosphate cells inside.
DC only, if customer requires AC integrated, pls contact our sales team to get a complete solution
System parameters:
Capacity: 2411kWh
Battery: 150pcs of 51.2V 280Ah air cooling battery pack
Key components:
BMS
Battery analog high-precision monitoring and reporting
Battery system operation alarm, display and report
Battery system protections
Thermal management system
It can realize the cooling and heating function.
Dehumidification module Optional
High environment adaptability
Battery compartment cooling methods: air cooling and liquid cooling options,
refer to the cooling method in the data sheet
Fully submerged gas fire extinguishing system
Type: Perfluorohexanone
Equipped with hydrogen, carbon monoxide, smoke, temperature sensors
High-Voltage Control Box
Equipped with circuit breakers, contactors, fuses, circulating current
control circuits, current sensors, battery cluster control and management
module, switching power supplies, and more. It provides functions such
as voltage and current collection, loop control, and protection for batteries.
Cell-Module-Battery Cluster
Utilizes ZT-TEK's self-developed and self-produced
lithium iron phosphate cells (ZT71173204-314Ah),
certified by third-party testing to meet GB36276-2018 & 2023 standards,
as well as IEC62619.
The cells exhibit high consistency, reliability, and stability.
IP54 Outdoor container
Including battery cluster,
engineering grade LED lighting system,
temperature control system, BMS,
fire protection system, monitoring system, etc.,
dehumidification air conditioning and infrared explosion-proof camera optional
Applications:
Grid support
Demand charge
Load shifiting
Energy buffer
Backup power
Off-grid power supply
Data sheet
Container Size | 20ft |
Model | ZT-EES-2411-51314 |
System capacity kWh | 2411.52 |
Battery parameters | |
Battery Module | 51.2V/314Ah |
Cooling method | Industrial air conditioning/Air cooling |
Battery type | LFP |
Battery cluster config. | 25 |
Total Number of cluster | 6 |
DC side parameters | |
Rated voltage V | 1280 |
Voltage range V | 1120~1140 |
Charging/discharging rate | 0.5C |
AC side parameters - for PCS selection reference | |
Rated power | 1260kW |
Rated voltage | 690V |
Rated current | 1054A |
Rated on-grid frequency | |
System parameters | |
IP Class | IP54 |
Working temperature range | -30℃~+55℃ |
Relative humidity | 0~95%,No condensation |
Max. altitude(m) | ≤3000(>3000 requires derating) |
Fire fighting system | Gas fire Protection (heptafluoropropane/perfluorohexanone), Firefighting Water Inlet |
Communication | Modbus-RTU/ Modbus-TCP/IEC61850 /IEC104 |